Home 
About Xinda      |      Business Administration      |      Global Marketing      |      Video Online      |      Certificates      |      Contact Us       |      
Goods elevators    [ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ]      <<Return



1、Configuration of control system

Ref.No elevator category series and type of control system max.landing stop number max.group control capacity main controller
1 Goods Elevator E10 14 single elevator PLC
2 E20 14 2 sets connected in parallel PLC
3 S60 16 2 sets connected in parallel 32-bit microcomputer

2、Standard functions
Ref.No Function Description E10 E20 S60 Ref.No Function Description E10 E20 S60
1 collective selective control × 18 out-of-service lock
2 attendant control × 19 runtime protection
3 signal control × × 20 close lock protection ×
4 bypass at full load 21 forced close ×
5 overload protection 22 automatic reserving call cancel ×
6 overload alarms 23 run times display
7 car light automatic control 24 runtime display ×
8 auto control for car fan 25 automatic opening time adjustment ×
9 open with hall call 26 automatic correction of unusual position
10 overspeed protection 27 automatic floor height detection
11 alarm device 28 automatic fault detection and storage
12 emergent lighting 29 low-speed self rescue function in case of faults
13 arrival gong 30 brake monitoring function
14 intercom 31 manual handwinding protection fuction
15 inspection operation 32 manual floor selection for self rescue in case of unusual door opening × ×
16 light-curtain protection × 33 communication between five parties
17 automatically return to main landing ×          

3、Optional functions
Ref.No Function Description E10 E20 S60 Ref.No Function Description E10 E20 S60
1 parallel control × 6 building monitoring interface ×
2 automatic evacuation on power failure 7 car error call cancel
3 fire return 8 security floor function ×
4 in-car visual monitoring system 9 taxi function
5 remote control × × 10 short landing function × ×

4、Parallel connection and group control functions
Ref.No Function Description E10 E20 S60 Ref.No Function Description E10 E20 S60
1 continuous service × 3 dynamic distribution wait ×
2 learn function ×          

Notes:
1、"√"indicates that it is an optional function ,and "×" indicates that it is not an optional function.
2、When selecting the functions,please first consult the sales department of our company.


©China Ningbo Xinda Group Co., Ltd.
Add: Dongwu Town, Yinzhou District, Ningbo City, Zhejiang Province, China 315113
Automatic Receiving Fax In 24 Hours: 0086-574-88336161